Blood Transfusion Research - Blood Donation, Blood Types, Leukemia

Blood Transfusion Research Today is a free monthly online journal that collates and summarizes the latest research about Blood Transfusion, including details on blood donation, blood types, leukemia.


Blood Transfusion Research Today

Home

View Latest Issue

Information About Blood Transfusion

Books on Blood Transfusion

Advertising in Research Today

View Other Research Today Publications



Comparison of two automated nucleic acid testing systems for simultaneous detection of human immunodeficiency virus and hepatitis C virus RNA and hepatitis B virus DNA.

Margaritis AR, Brown SM, Seed CR, Kiely P, D'Agostino B, Keller AJ

Australian Red Cross Blood Service-Enterprise, 97 Great Eastern Highway, Rivervale, Western Australia 6103. amargaritis@arcbs.redcross.org.au

BACKGROUND: Recently developed nucleic acid testing (NAT) assays incorporating simultaneous detection of human immunodeficiency virus (HIV), hepatitis C virus (HCV), and hepatitis B virus (HBV) have made HBV NAT screening more feasible for blood services. This study compared the performance of two "multiplex" NAT assays and their automated testing platforms. STUDY DESIGN AND METHODS: The HBV NAT yield rate was estimated by testing 10,397 Hong Kong (HK) donor samples concurrently on the PROCLEIX ULTRIO (Ultrio) assay as individual donor samples with the TIGRIS and on the cobas TaqScreen multiplex (cobas MPX) test in pools of 6 with the cobas s 201. Analytical sensitivity was assessed by probit analysis of diluted international standards and operational performance was compared. RESULTS: Each system detected two different HBV NAT yield samples for a combined rate of 0.04 percent. One additional sample was reactive on the cobas MPX test but remained unresolved. The 95 percent detection limits for HIV-1, HBV, and HCV were 42.2, 12.2, and 2.0 IU per mL, respectively, for Ultrio and 50.5, 8.4, and 6.0 IU per mL for the cobas MPX. The invalid test and failed run rates were 0.05 and 2.92 percent, respectively, for the TIGRIS and 2.39 and 5.53 percent for the cobas s 201. CONCLUSION: Clinical sensitivity for HBV in HK blood donors was equivalent, as was the analytical sensitivity for HIV-1 and HBV; however, the Ultrio assay had a higher analytical sensitivity for HCV. Despite a shorter downtime and mean time of repair for the cobas s 201, the TIGRIS demonstrated better overall operational performance.

Published 20 September 2007 in Transfusion, 47(10): 1783-93.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Blood Transfusion Research Today. All Rights Reserved.



Blood Transfusion Research Today Archive:

Volume 1 (2004)
  Issue 1 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Blood Transfusion Books

Rossi's Principles of Transfusion Medicine (Simon, Rossi's Principles of Transfusion Medicine)

Rossi's Principles of Transfusion Medicine (Simon, Rossi's Principles of Transfusion Medicine)